Test cases for Dragon Naturally Speaking + Chrome Test case: Use "Click <text>" (Activate item by name) Launch Dragon Naturally Speaking and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "Click <text>"
(Activate item by name) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes Test case: Use Click <role> (Click Type) Launch Dragon Naturally Speaking and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: Click <role>
(Click Type) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch Dragon Naturally Speaking and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: (multiple commands)
(Multiple commands were used) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test case: Use "{speak text to type}" (dictate) Launch Dragon Naturally Speaking and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "{speak text to type}"
(dictate) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST allow data entry Examples:
Voice control software might allow someone to dictate data into a field once it is focused. Resultunknown pass fail partial
Notes Test cases for Dragon Naturally Speaking + IE The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Dragon Naturally Speaking + Firefox The test has not been configured for this combination. Please open a GitHub issue.
Test cases for JAWS + Chrome Test case: Use Down arrow (Read next item) to navigate forward to `input[type="time"]` Launch JAWS and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Down arrow
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch JAWS and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use f (Next form field) to navigate forward to `input[type="time"]` Launch JAWS and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: f
(Next form field) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use Insert + F3 (Open element list) Launch JAWS and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: Insert + F3
(Open element list) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use <keyboard command> (Keyboard command while in forms or application mode) to navigate forward to `input[type="time"]` Launch JAWS and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: <keyboard command>
(Keyboard command while in forms or application mode) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch JAWS and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: (multiple commands)
(Multiple commands were used) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for JAWS + Edge Test case: Use Down arrow (Read next item) to navigate forward to `input[type="time"]` Launch JAWS and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Down arrow
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch JAWS and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use f (Next form field) to navigate forward to `input[type="time"]` Launch JAWS and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: f
(Next form field) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use Insert + F3 (Open element list) Launch JAWS and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: Insert + F3
(Open element list) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use <keyboard command> (Keyboard command while in forms or application mode) to navigate forward to `input[type="time"]` Launch JAWS and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: <keyboard command>
(Keyboard command while in forms or application mode) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch JAWS and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: (multiple commands)
(Multiple commands were used) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for JAWS + Firefox Test case: Use Down arrow (Read next item) to navigate forward to `input[type="time"]` Launch JAWS and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Down arrow
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch JAWS and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use f (Next form field) to navigate forward to `input[type="time"]` Launch JAWS and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: f
(Next form field) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use Insert + F3 (Open element list) Launch JAWS and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: Insert + F3
(Open element list) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use <keyboard command> (Keyboard command while in forms or application mode) to navigate forward to `input[type="time"]` Launch JAWS and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: <keyboard command>
(Keyboard command while in forms or application mode) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch JAWS and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: (multiple commands)
(Multiple commands were used) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for JAWS + IE Test case: Use Down arrow (Read next item) to navigate forward to `input[type="time"]` Launch JAWS and IE. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Down arrow
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch JAWS and IE. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use f (Next form field) to navigate forward to `input[type="time"]` Launch JAWS and IE. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: f
(Next form field) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use Insert + F3 (Open element list) Launch JAWS and IE. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: Insert + F3
(Open element list) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use <enter text> (enter text) on the target of `input[type="time"]` Launch JAWS and IE. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: target Keyboard focus is: target Mode is: auto (do not explicitly change the mode) Issue the command: <enter text>
(enter text) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test cases for Narrator + Edge Test case: Use Down arrow (Jump to next item (scan mode)) to navigate forward to `input[type="time"]` Launch Narrator and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Down arrow
(Jump to next item (scan mode)) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch Narrator and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use f (Next form field) to navigate forward to `input[type="time"]` Launch Narrator and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: f
(Next form field) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use Enter or Space Bar (Activate Item (primary action)) to navigate forward to `input[type="time"]` Launch Narrator and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Enter or Space Bar
(Activate Item (primary action)) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch Narrator and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: (multiple commands)
(Multiple commands were used) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for Narrator + Firefox The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Narrator + Chrome The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Narrator + IE The test has not been configured for this combination. Please open a GitHub issue.
Test cases for NVDA + Chrome Test case: Use down arrow (Read next item) to navigate forward to `input[type="time"]` Launch NVDA and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: down arrow
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch NVDA and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use f (Next form field) to navigate forward to `input[type="time"]` Launch NVDA and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: f
(Next form field) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use NVDA + F7 (Open Elements List) Launch NVDA and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: NVDA + F7
(Open Elements List) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use <enter text> (enter text) on the target of `input[type="time"]` Launch NVDA and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: target Keyboard focus is: target Mode is: auto (do not explicitly change the mode) Issue the command: <enter text>
(enter text) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch NVDA and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: (multiple commands)
(Multiple commands were used) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test cases for NVDA + Edge Test case: Use down arrow (Read next item) to navigate forward to `input[type="time"]` Launch NVDA and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: down arrow
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch NVDA and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use f (Next form field) to navigate forward to `input[type="time"]` Launch NVDA and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: f
(Next form field) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use NVDA + F7 (Open Elements List) Launch NVDA and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: NVDA + F7
(Open Elements List) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use <enter text> (enter text) on the target of `input[type="time"]` Launch NVDA and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: target Keyboard focus is: target Mode is: auto (do not explicitly change the mode) Issue the command: <enter text>
(enter text) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch NVDA and Edge. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: (multiple commands)
(Multiple commands were used) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test cases for NVDA + Firefox Test case: Use down arrow (Read next item) to navigate forward to `input[type="time"]` Launch NVDA and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: down arrow
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch NVDA and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use f (Next form field) to navigate forward to `input[type="time"]` Launch NVDA and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: f
(Next form field) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use NVDA + F7 (Open Elements List) Launch NVDA and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: NVDA + F7
(Open Elements List) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use <enter text> (enter text) on the target of `input[type="time"]` Launch NVDA and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: target Keyboard focus is: target Mode is: auto (do not explicitly change the mode) Issue the command: <enter text>
(enter text) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch NVDA and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: (multiple commands)
(Multiple commands were used) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for NVDA + IE The test has not been configured for this combination. Please open a GitHub issue.
Test cases for TalkBack + Chrome Test case: Use Swipe right (or alt+right arrow) (Read next item) to navigate forward to `input[type="time"]` Launch TalkBack and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Swipe right (or alt+right arrow)
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Swipe down (alt+c) (next control (correct reading control must be selected)) to navigate forward to `input[type="time"]` Launch TalkBack and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Swipe down (alt+c)
(next control (correct reading control must be selected)) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use double tap (or alt+enter) (Activate button) to navigate forward to `input[type="time"]` Launch TalkBack and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: double tap (or alt+enter)
(Activate button) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch TalkBack and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: (multiple commands)
(Multiple commands were used) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for TalkBack + Firefox The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Voice Access (Android) + Chrome Test case: Use "Tap <text>" or just "<text>" (Activate item by name) Launch Voice Access (Android) and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "Tap <text>" or just "<text>"
(Activate item by name) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes Test case: Use "Show numbers" (Turn on the numbers overlay) Launch Voice Access (Android) and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "Show numbers"
(Turn on the numbers overlay) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch Voice Access (Android) and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: (multiple commands)
(Multiple commands were used) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for Voice Access (Android) + Firefox The test has not been configured for this combination. Please open a GitHub issue.
Test cases for VoiceOver (iOS) + Safari Test case: Use Swipe Right (Next item) to navigate forward to `input[type="time"]` Launch VoiceOver (iOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Swipe Right
(Next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Swipe down (next form control (correct item type must be selected)) to navigate forward to `input[type="time"]` Launch VoiceOver (iOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Swipe down
(next form control (correct item type must be selected)) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use Double tap (Activate Button) to navigate forward to `input[type="time"]` Launch VoiceOver (iOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Double tap
(Activate Button) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch VoiceOver (iOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: (multiple commands)
(Multiple commands were used) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for VoiceOver (iOS) + Chrome The test has not been configured for this combination. Please open a GitHub issue.
Test cases for VoiceOver (macOS) + Safari Test case: Use VO + Right arrow (Read next item) to navigate forward to `input[type="time"]` Launch VoiceOver (macOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: VO + Right arrow
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch VoiceOver (macOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use VO + Command + J (Next Form Control) to navigate forward to `input[type="time"]` Launch VoiceOver (macOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: VO + Command + J
(Next Form Control) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use VO + U (Open Rotor) Launch VoiceOver (macOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metMode is: auto (do not explicitly change the mode) Issue the command: VO + U
(Open Rotor) After issuing the command, virtual focus should be: na Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use <enter text> (enter text) on the target of `input[type="time"]` Launch VoiceOver (macOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: target Keyboard focus is: target Mode is: auto (do not explicitly change the mode) Issue the command: <enter text>
(enter text) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test cases for VoiceOver (macOS) + Chrome The test has not been configured for this combination. Please open a GitHub issue.
Test cases for VoiceOver (macOS) + Firefox The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Orca + Firefox Test case: Use down arrow (Read next item) to navigate forward to `input[type="time"]` Launch Orca and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: down arrow
(Read next item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use Tab (Read next focusable item) to navigate forward to `input[type="time"]` Launch Orca and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Read next focusable item) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes Test case: Use alt + shift + f (Open list of form fields) to navigate forward to `input[type="time"]` Launch Orca and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: alt + shift + f
(Open list of form fields) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes input[type="time"] element, MUST convey the current value Resultunknown pass fail partial
Notes input[type="time"] element, SHOULD provide shortcuts to jump to this role Resultunknown pass fail partial
Notes Test case: Use <enter text> (enter text) on the target of `input[type="time"]` Launch Orca and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: target Keyboard focus is: target Mode is: auto (do not explicitly change the mode) Issue the command: <enter text>
(enter text) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use <keyboard command> (Keyboard command while in forms or application mode) to navigate forward to `input[type="time"]` Launch Orca and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: <keyboard command>
(Keyboard command while in forms or application mode) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey changes in value Examples:
When the user enter texts, the screen reader will announce it back to them. Resultunknown pass fail partial
Notes Test case: Use Tab (Next form field) to navigate forward to `input[type="datetime-local"]` Launch Orca and Firefox. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Position and configure the screen reader so that the following conditions are metVirtual focus is: before target Keyboard focus is: before target Mode is: auto (do not explicitly change the mode) Issue the command: Tab
(Next form field) After issuing the command, virtual focus should be: target Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for Orca + Chrome The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Voice Control (iOS) + Safari Test case: Use "Tap <text>" (Activate item by name) Launch Voice Control (iOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "Tap <text>"
(Activate item by name) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch Voice Control (iOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: (multiple commands)
(Multiple commands were used) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test cases for Voice Control (MacOS) + Safari Test case: Use "Click <text>" (Activate item by name) Launch Voice Control (MacOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "Click <text>"
(Activate item by name) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes Test case: Use "Show numbers" (Turn on the numbers overlay) Launch Voice Control (MacOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "Show numbers"
(Turn on the numbers overlay) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes Test case: Use "{speak text to type}" (dictate) Launch Voice Control (MacOS) and Safari. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "{speak text to type}"
(dictate) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST allow data entry Examples:
Voice control software might allow someone to dictate data into a field once it is focused. Resultunknown pass fail partial
Notes Test cases for Voice Control (MacOS) + Chrome The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Voice Control (MacOS) + Firefox The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Windows Speech Recognition + Edge The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Windows Speech Recognition + Chrome Test case: Use "Click <text>" (Activate item by name) Launch Windows Speech Recognition and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "Click <text>"
(Activate item by name) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its name Examples:
A screen reader will announce the name (label). Voice control software will let the user say something like "click <name>" to activate the control. Resultunknown pass fail partial
Notes Test case: Use "Show numbers" (Turn on the numbers overlay) Launch Windows Speech Recognition and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "Show numbers"
(Turn on the numbers overlay) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST convey its role Examples:
A screen reader might be announce the role as "text input", "edit", "edit time", etc. Voice control software will let the user say something like "click text box" to focus a the input or flag the role with a number. Resultunknown pass fail partial
Notes Test case: Use (multiple commands) (Multiple commands were used) Launch Windows Speech Recognition and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="datetime-local"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: (multiple commands)
(Multiple commands were used) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST support the date picker widget and native controls Examples:
If implemented as a text field, this is not applicable If implemented as a date picker, the screen reader must convey appropriate semantics If implemented as multiple text inputs (one each for month, day, and year), the screen reader must convey appropriate semantics Voice control software will let the user activate and fill the appropriate controls Resultunknown pass fail partial
Notes Test case: Use "{speak text to type}" (dictate) Launch Windows Speech Recognition and Chrome. Navigate to the test page . Find the target element(s) that you will test against. Identify all elements that match this selector:input[type="time"]
If multiple elements match the selector, repeat this test for all instances. However, choose a single instance to report against. If you feel that the selector should be more specific, please open a GitHub Issue. Issue the command: "{speak text to type}"
(dictate) Record results for the relevant expectations Output Notes If support is hidden behind non-default settings, briefly describe that setting input[type="time"] element, MUST allow data entry Examples:
Voice control software might allow someone to dictate data into a field once it is focused. Resultunknown pass fail partial
Notes Test cases for Windows Voice Access + Edge The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Windows Voice Access + Chrome The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Windows Keyboard + Chrome The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Windows Keyboard + Firefox The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Windows Keyboard + Edge The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Mac Keyboard + Chrome The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Mac Keyboard + Safari The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Mac Keyboard + Firefox The test has not been configured for this combination. Please open a GitHub issue.
Test cases for iOS Keyboard + Safari The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Android Keyboard + Chrome The test has not been configured for this combination. Please open a GitHub issue.
Test cases for Android Keyboard + Firefox The test has not been configured for this combination. Please open a GitHub issue.