Test: ARIA readonly grid (Narrator/Edge)

Expectation: grid role: SHOULD switch to interaction mode

Details
PropertyValue
Supportnone
Grading Note: There is no known/documented support. There may still be support for this expectation, but it is undocumented. If this is the case, please report this issue.
AT NameNarrator
AT VersionWindows 10 version 1909
Browser NameEdge
Browser Version44
OS versionWindows 10 version 1909
Date2020-05-15
Notes

Commands and Output

These are specific commands used to access the target element in the test, along with the resulting output.

CommandResultOutputNotes
next_item (Down arrow)fail"table, grid example, has 3 rows, 2 columns, grid example, data grid, columns date, contains 3 rows, column header, column header, date, row 1 of 3, column 1 of 2 "Grading note: This command may be expected to fail. This result simply indicates that it did not yield support.
previous_item (Up arrow)fail"grid example, data grid, columns date, contains 3 rows"Grading note: This command may be expected to fail. This result simply indicates that it did not yield support.
next_focusable_item (Tab)fail"table grid example, has 3 rows, two columns, date, readonly, column header, column header, date, row column 1 of 3, column 1 of 2 "Grading note: This command may be expected to fail. This result simply indicates that it did not yield support.